
30l 48l 64l Laboratory Constant Temperature Incubator
Multi-capacity laboratory incubator providing precise temperature control (RT+5°C to 80°C) with ±0.2°C stability for cell culture, microbiology, and analytical applications.
| Automation Level | semi-automated |
| BJPX-H48II | BJPX-H64II |
| BJPX-H123II | BJPX-H230II |
| 45L | 65L |
| 125L | 230L |
| Temp.Range | RT+5~80℃ |
The ConductScience Laboratory Constant Temperature Incubator provides precise environmental control for biological samples, cell cultures, and temperature-sensitive materials across multiple capacity configurations. Available in 30L, 45L, 65L, 125L, and 230L internal volumes, this incubator maintains stable temperatures from ambient +5°C to 80°C with ±0.2°C fluctuation control.
The unit features programmable time settings from 1 to 9999 minutes, dual adjustable shelving systems, and stainless steel construction suitable for sterile applications. Power consumption varies by model (150W to 700W) with standard AC220V or optional AC110V power supply configurations.
How It Works
The incubator operates through forced air circulation with precise temperature sensing and PID control algorithms. Internal heating elements generate thermal energy while temperature sensors continuously monitor chamber conditions, maintaining setpoint temperatures through feedback control systems.
The chamber design incorporates uniform air distribution patterns to minimize thermal gradients across shelf levels. Adjustable shelving allows vertical space optimization while maintaining consistent temperature zones throughout the internal volume.
Digital controllers provide programmable timing functions with automatic shutdown capabilities, enabling unattended operation for extended incubation periods while preventing temperature drift and sample degradation.
Features & Benefits
Automation Level
- semi-automated
BJPX-H48II
- BJPX-H64II
BJPX-H123II
- BJPX-H230II
45L
- 65L
125L
- 230L
Temp.Range
- RT+5~80℃
Temp.Fluctuation
- ±0.2℃
Time Setting
- 1~9999mins
Shelves
- 2 pcsladjustable
Consumption
- 150W
250W
- 500W
600W
- 700W
lnternal Size(mm)
- 310*310*310
Brand
- ConductScience
Research Domain
- Analytical Chemistry
- Cell Biology
- Environmental Monitoring
- Food Science
- Microbiology
- Pharmaceutical QC
Capacity
- 30L
Power/Voltage
- AC220V±10%, 50/60Hz(Standard); AC110+10%, 60Hz(Optional)
Weight
- 92.79 kg
Dimensions
- L: 12.2 mm
- W: 12.2 mm
- H: 12.2 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Temperature Stability | ±0.2°C fluctuation control | Entry-level models often provide ±0.5°C to ±1.0°C stability | Tighter temperature control reduces variability in temperature-sensitive biological processes and analytical procedures. |
| Capacity Range | 30L to 230L internal volume options | Basic incubators commonly offer single capacity configurations | Scalable platform allows laboratories to select appropriate capacity for current needs while maintaining consistent performance characteristics. |
| Timer Programming | 1-9999 minute digital timer control | Manual models require constant monitoring | Automated timing prevents over-incubation and enables unattended operation for extended protocols. |
| Construction Material | Stainless steel chamber construction | Coated steel chambers in budget models | Enhanced chemical resistance and easier decontamination for sterile applications and corrosive sample types. |
| Power Compatibility | AC220V standard with AC110V optional configuration | Fixed voltage configurations require local power adaptation | International laboratory compatibility reduces installation complexity and electrical modification requirements. |
This incubator series combines precise temperature control with flexible capacity options and robust construction. The ±0.2°C stability and programmable timing provide reliable performance for both routine and critical applications requiring consistent thermal conditions.
Practical Tips
Perform multi-point temperature calibration using calibrated reference thermometers placed at different shelf levels and chamber positions.
Why: Verifies temperature uniformity across the working volume and identifies any thermal gradients that could affect sample consistency.
Clean internal surfaces weekly with appropriate disinfectants and inspect door seals for proper closure and contamination prevention.
Why: Prevents microbial contamination buildup and maintains chamber integrity for sterile culture applications.
Allow 30-60 minute equilibration time after loading samples before beginning time-sensitive incubation periods.
Why: Compensates for thermal mass effects when cold samples are introduced, ensuring accurate incubation timing from target temperature.
Monitor power consumption patterns to identify heating element degradation or insulation problems before they affect temperature stability.
Why: Early detection of component wear prevents unexpected temperature excursions that could compromise critical samples.
Log temperature readings at regular intervals during critical incubations using independent temperature monitoring devices.
Why: Provides documentation trail for regulated applications and early warning of control system drift or failure.
Install appropriate electrical protection and ensure adequate ventilation around the unit to prevent overheating of control electronics.
Why: Prevents electrical hazards and extends component lifespan by maintaining proper operating temperatures for control systems.
Distribute sample containers evenly across shelf space and avoid overloading to maintain proper air circulation patterns.
Why: Ensures uniform temperature distribution to all samples and prevents local hot spots or cold zones within the chamber.
Setup Guide
What’s in the Box
- Laboratory incubator main unit
- 2 adjustable stainless steel shelves
- Power cord (region-specific)
- Digital control panel with timer
- User manual and specifications
- Temperature calibration certificate (typical)
Warranty
ConductScience provides a standard one-year manufacturer warranty covering defects in materials and workmanship. Technical support includes installation guidance, calibration procedures, and troubleshooting assistance throughout the warranty period.
Compliance
What is the temperature uniformity across different shelf levels?
The forced air circulation design minimizes thermal gradients, though specific uniformity specifications should be confirmed in the product datasheet for critical applications requiring precise temperature mapping.
Can the unit maintain temperatures below room temperature?
No, the minimum operating temperature is room temperature +5°C. Refrigerated incubator models are required for sub-ambient temperature applications.
What type of door seal is used for contamination control?
Consult product datasheet for specific door seal specifications. Standard laboratory incubators typically use silicone gaskets for adequate sealing in non-sterile applications.
Is the internal chamber autoclavable for sterilization?
The stainless steel construction allows chemical disinfection, but autoclave compatibility of the complete chamber assembly should be verified in the technical specifications.
What calibration procedures are recommended for temperature accuracy?
Annual calibration using NIST-traceable reference thermometers is standard practice. Multi-point calibration across the operating range ensures accuracy for critical applications.
Can multiple units be operated from the same power circuit?
Power consumption ranges from 150W to 700W depending on model. Circuit capacity should accommodate peak heating loads plus any other laboratory equipment on the same circuit.
What ambient temperature range is required for proper operation?
Consult installation specifications for ambient operating conditions. Standard laboratory incubators typically require 15-30°C ambient temperature ranges.
Have a question about this product?
Accessories
Enhance your setup with compatible accessories





