Double Cannula System Pack
The Cannula System Packs are the ultimate solution for precise and controlled delivery in laboratory research. Our Multiple Cannula System Packs are designed to provide researchers with a reliable and efficient method for delivering substances, co...
| outer_diameter_options | 0.41mm (27G), 0.48mm (26G), 0.64mm (23G) |
| center_to_center_distance_range | 0.5mm to 3.0mm |
| base_height | 7.8mm (standard), 5.5mm (mice) |
| mounting_screw_size | M3.5, M5 |
| cannula_type | Double cannula system |
| administration_method | Unilateral intracranial |
The cannula implantation system is an accepted method of acute and chronic intracranial drug administration for animal experiment. Our cannula system includes guide cannula, dummy cannula, internal cannula and fixing screw. Together with our stereotaxic instruments, holders, fixing screws, PE cannulas, injection pumps and other related products, this system provide a set of simple and effective experimental tool of unilateral intracranial administration for neuroscientists. More importantly, we offer users can customized cannulas based on their specific experimental requirements.
| SKU | Product Description | UOM |
| RWD-62021 | Guide Cannula-Double/O.D.0.48mm-26G/C.C0.5/B7.8/M3.5 | Pcs |
| RWD-62022 | Guide Cannula-Double/O.D.0.48mm-26G/C.C0.6/B7.8/M3.5 | Pcs |
| RWD-62023 | Guide Cannula-Double/O.D.0.48mm-26G/C.C0.8/B7.8/M3.5 | Pcs |
| RWD-62024 | Guide Cannula-Double/O.D.0.48mm-26G/C.C1.0/B7.8/M3.5 | Pcs |
| RWD-62025 | Guide Cannula-Double/O.D.0.48mm-26G/C.C1.2/B7.8/M3.5 | Pcs |
| RWD-62026 | Guide Cannula-Double/O.D.0.48mm-26G/C.C1.3/B7.8/M3.5 | Pcs |
| RWD-62027 | Guide Cannula-Double/O.D.0.48mm-26G/C.C1.4/B7.8/M3.5 | Pcs |
| RWD-62028 | Guide Cannula-Double/O.D.0.48mm-26G/C.C1.5/B7.8/M3.5 | Pcs |
| RWD-62029 | Guide Cannula-Double/O.D.0.48mm-26G/C.C1.6/B7.8/M3.5 | Pcs |
| RWD-62030 | Guide Cannula-Double/O.D.0.48mm-26G/C.C1.8/B7.8/M3.5 | Pcs |
| RWD-62031 | Guide Cannula-Double/O.D.0.48mm-26G/C.C2.0/B7.8/M3.5 | Pcs |
| RWD-62032 | Guide Cannula-Double/O.D.0.48mm-26G/C.C2.2/B7.8/M5 | Pcs |
| RWD-62033 | Guide Cannula-Double/O.D.0.48mm-26G/C.C2.4/B7.8/M5 | Pcs |
| RWD-62034 | Guide Cannula-Double/O.D.0.48mm-26G/C.C2.6/B7.8/M5 | Pcs |
| RWD-62035 | Guide Cannula-Double/O.D.0.48mm-26G/C.C2.7/B7.8/M5 | Pcs |
| RWD-62036 | Guide Cannula-Double/O.D.0.48mm-26G/C.C3.0/B7.8/M5 | Pcs |
| RWD-62037 | Guide Cannula-Double/O.D.0.64mm-23G/C.C0.8/B7.8/M3.5 | Pcs |
| RWD-62038 | Guide Cannula-Double/O.D.0.64mm-23G/C.C1.0/B7.8/M3.5 | Pcs |
| RWD-62039 | Guide Cannula-Double/O.D.0.64mm-23G/C.C1.2/B7.8/M3.5 | Pcs |
| RWD-62040 | Guide Cannula-Double/O.D.0.64mm-23G/C.C1.3/B7.8/M3.5 | Pcs |
| RWD-62041 | Guide Cannula-Double/O.D.0.64mm-23G/C.C1.4/B7.8/M3.5 | Pcs |
| RWD-62042 | Guide Cannula-Double/O.D.0.64mm-23G/C.C1.5/B7.8/M3.5 | Pcs |
| RWD-62043 | Guide Cannula-Double/O.D.0.64mm-23G/C.C1.8/B7.8/M3.5 | Pcs |
| RWD-62044 | Guide Cannula-Double/O.D.0.64mm-23G/C.C2.0/B7.8/M5 | Pcs |
| RWD-62045 | Guide Cannula-Double/O.D.0.64mm-23G/C.C2.2/B7.8/M5 | Pcs |
| RWD-62046 | Guide Cannula-Double/O.D.0.64mm-23G/C.C2.4/B7.8/M5 | Pcs |
| RWD-62047 | Guide Cannula-Double/O.D.0.64mm-23G/C.C2.5/B7.8/M5 | Pcs |
| RWD-62048 | Guide Cannula-Double/O.D.0.64mm-23G/C.C2.8/B7.8/M5 | Pcs |
| RWD-62049 | Guide Cannula-Double/O.D.0.64mm-23G/C.C3.0/B7.8/M5 | Pcs |
| RWD-62050 | Guide Cannula-Mice/Double/O.D.0.48mm-26G/C.C0.5/B5.5/M3.5 | Pcs |
| RWD-62051 | Guide Cannula-Mice/Double/O.D.0.48mm-26G/C.C0.6/B5.5/M3.5* | Pcs |
| RWD-62052 | Guide Cannula-Mice/Double/O.D.0.48mm-26G/C.C0.8/B5.5/M3.5 | Pcs |
| RWD-62053 | Guide Cannula-Mice/Double/O.D.0.48mm-26G/C.C1.0/B5.5/M3.5 | Pcs |
| RWD-62054 | Guide Cannula-Mice/Double/O.D.0.48mm-26G/C.C1.2/B5.5/M3.5 | Pcs |
| RWD-62055 | Guide Cannula-Mice/Double/O.D.0.48mm-26G/C.C1.3/B5.5/M3.5 | Pcs |
| RWD-62056 | Guide Cannula-Mice/Double/O.D.0.48mm-26G/C.C1.4/B5.5/M3.5 | Pcs |
| RWD-62057 | Guide Cannula-Mice/Double/O.D.0.48mm-26G/C.C1.5/B5.5/M3.5 | Pcs |
| RWD-62058 | Guide Cannula-Mice/Double/O.D.0.48mm-26G/C.C1.6/B5.5/M3.5 | Pcs |
| RWD-62059 | Guide Cannula-Mice/Double/O.D.0.48mm-26G/C.C1.8/B5.5/M3.5 | Pcs |
| RWD-62060 | Guide Cannula-Mice/Double/O.D.0.48mm-26G/C.C2.0/B5.5/M3.5 | Pcs |
| RWD-62061 | Guide Cannula-Double/O.D.0.41mm-27G/C.C0.5/B7.8/M3.5 | Pcs |
| RWD-62062 | Guide Cannula-Double/O.D.0.41mm-27G/C.C0.6/B7.8/M3.5 | Pcs |
| RWD-62063 | Guide Cannula-Double/O.D.0.41mm-27G/C.C0.8/B7.8/M3.5 | Pcs |
| RWD-62064 | Guide Cannula-Double/O.D.0.41mm-27G/C.C1.0/B7.8/M3.5 | Pcs |
| RWD-62065 | Guide Cannula-Double/O.D.0.41mm-27G/C.C1.2/B7.8/M3.5 | Pcs |
| RWD-62066 | Guide Cannula-Double/O.D.0.41mm-27G/C.C1.3/B7.8/M3.5 | Pcs |
| RWD-62067 | Guide Cannula-Double/O.D.0.41mm-27G/C.C1.4/B7.8/M3.5 | Pcs |
| RWD-62068 | Guide Cannula-Double/O.D.0.41mm-27G/C.C1.5/B7.8/M3.5 | Pcs |
| RWD-62069 | Guide Cannula-Double/O.D.0.41mm-27G/C.C1.6/B7.8/M3.5 | Pcs |
| RWD-62070 | Guide Cannula-Double/ O.D.0.41mm-27G/ C.C1.8/B7.8/M3.5 | Pcs |
| RWD-62071 | Guide Cannula-Double/ O.D.0.41mm-27G/C.C2.0/B7.8/M3.5 | Pcs |
| RWD-62121 | Dummy Cannula-Double/O.D.0.30mm/C.C0.5/Mates with M3.5 | Pcs |
| RWD-62122 | Dummy Cannula-Double/O.D.0.30mm/C.C0.6/Mates with M3.5 | Pcs |
| RWD-62123 | Dummy Cannula-Double/O.D.0.30mm/C.C0.8/Mates with M3.5 | Pcs |
| RWD-62124 | Dummy Cannula-Double/O.D.0.30mm/C.C1.0/Mates with M3.5 | Pcs |
| RWD-v62125 | Dummy Cannula-Double/O.D.0.30mm/C.C1.2/Mates with M3.5 | Pcs |
| RWD-62126 | Dummy Cannula-Double/O.D.0.30mm/C.C1.3/Mates with M3.5 | Pcs |
| RWD-62127 | Dummy Cannula-Double/O.D.0.30mm/C.C1.4/Mates with M3.5 | Pcs |
| RWD-62128 | Dummy Cannula-Double/O.D.0.30mm/C.C1.5/Mates with M3.5 | Pcs |
| RWD-62129 | Dummy Cannula-Double/O.D.0.30mm/C.C1.6/Mates with M3.5 | Pcs |
| RWD-62130 | Dummy Cannula-Double/O.D.0.30mm/C.C1.8/Mates with M3.5 | Pcs |
| RWD-62131 | Dummy Cannula-Double/O.D.0.30mm/C.C2.0/Mates with M3.5 | Pcs |
| RWD-62132 | Dummy Cannula-Double/O.D.0.30mm/C.C2.2/Mates with M5 | Pcs |
| RWD-62133 | Dummy Cannula-Double/O.D.0.30mm/C.C2.4/Mates with M5 | Pcs |
| RWD-62134 | Dummy Cannula-Double/O.D.0.30mm/C.C2.6/Mates with M5 | Pcs |
| RWD-62135 | Dummy Cannula-Double/O.D.0.30mm/C.C2.7/Mates with M5 | Pcs |
| RWD-62136 | Dummy Cannula-Double/O.D.0.30mm/C.C3.0/Mates with M5 | Pcs |
| RWD-62137 | Dummy Cannula-Double/O.D.0.40mm/C.C0.8/Mates with M3.5 | Pcs |
| RWD-62138 | Dummy Cannula-Double/O.D.0.40mm/C.C1.0/Mates with M3.5 | Pcs |
| RWD-62139 | Dummy Cannula-Double/O.D.0.40mm/C.C1.2/Mates with M3.5 | Pcs |
| RWD-62140 | Dummy Cannula-Double/O.D.0.40mm/C.C1.3/Mates with M3.5 | Pcs |
| RWD-62141 | Dummy Cannula-Double/O.D.0.40mm/C.C1.4/Mates with M3.5 | Pcs |
| RWD-62142 | Dummy Cannula-Double/O.D.0.40mm/C.C1.5/Mates with M3.5 | Pcs |
| RWD-62143 | Dummy Cannula-Double/O.D.0.40mm/C.C1.8/Mates with M3.5 | Pcs |
| RWD-62144 | Dummy Cannula-Double/O.D.0.40mm/C.C2.0/Mates with M5 | Pcs |
| RWD-62145 | Dummy Cannula-Double/O.D.0.40mm/C.C2.2/Mates with M5 | Pcs |
| RWD-62146 | Dummy Cannula-Double/O.D.0.40mm/C.C2.4/Mates with M5 | Pcs |
| RWD-62147 | Dummy Cannula-Double/O.D.0.40mm/C.C2.5/Mates with M5 | Pcs |
| RWD-62148 | Dummy Cannula-Double/O.D.0.40mm/C.C2.8/Mates with M5 | Pcs |
| RWD-62149 | Dummy Cannula-Double/O.D.0.40mm/C.C3.0/Mates with M5 | Pcs |
| RWD-62161 | Dummy Cannula-Double/O.D.0.20mm/C.C0.5/Mates with M3.5 | Pcs |
| RWD-62162 | Dummy Cannula-Double/O.D.0.20mm/C.C0.6/Mates with M3.5 | Pcs |
| RWD-62163 | Dummy Cannula-Double/O.D.0.20mm/C.C0.8/Mates with M3.5 | Pcs |
| RWD-62164 | Dummy Cannula-Double/O.D.0.20mm/C.C1.0/Mates with M3.5 | Pcs |
| RWD-62165 | Dummy Cannula-Double/O.D.0.20mm/C.C1.2/Mates with M3.5 | Pcs |
| RWD-62166 | Dummy Cannula-Double/O.D.0.20mm/C.C1.3/Mates with M3.5 | Pcs |
| RWD-62167 | Dummy Cannula-Double/O.D.0.20mm/C.C1.4/Mates with M3.5 | Pcs |
| RWD-62168 | Dummy Cannula-Double/O.D.0.20mm/C.C1.5/Mates with M3.5 | Pcs |
| RWD-62169 | Dummy Cannula-Double/O.D.0.20mm/C.C1.6/Mates with M3.5 | Pcs |
| RWD-62170 | Dummy Cannula-Double/O.D.0.20mm/C.C1.8/Mates with M3.5 | Pcs |
| RWD-62171 | Dummy Cannula-Double/O.D.0.20mm/C.C2.0/Mates with M3.5 | Pcs |
| RWD-62223 | Injector-Double/O.D.0.30mm-30G/C.C0.8/Mates with M3.5 | Pcs |
| RWD-62224 | Injector-Double/O.D.0.30mm-30G/C.C1.0/Mates with M3.5 | Pcs |
| RWD-62225 | Injector-Double/O.D.0.30mm-30G/C.C1.2/Mates with M3.5 | Pcs |
| RWD-62226 | Injector-Double/O.D.0.30mm-30G/C.C1.3/Mates with M3.5 | Pcs |
| RWD-62227 | Injector-Double/O.D.0.30mm-30G/C.C1.4/Mates with M3.5 | Pcs |
| RWD-62228 | Injector-Double/O.D.0.30mm-30G/C.C1.5/Mates with M3.5 | Pcs |
| RWD-62229 | Injector-Double/O.D.0.30mm-30G/C.C1.6/Mates with M3.5 | Pcs |
| RWD-62230 | Injector-Double/O.D.0.30mm-30G/C.C1.8/Mates with M3.5 | Pcs |
| RWD-62231 | Injector-Double/O.D.0.30mm-30G/C.C2.0/Mates with M3.5 | Pcs |
| RWD-62232 | Injector-Double/O.D.0.30mm-30G/C.C2.2/Mates with M5 | Pcs |
| RWD-62233 | Injector-Double/O.D.0.30mm-30G/C.C2.4/Mates with M5 | Pcs |
| RWD-62234 | Injector-Double/O.D.0.30mm-30G/C.C2.6/Mates with M5 | Pcs |
| RWD-62235 | Injector-Double/O.D.0.30mm-30G/C.C2.7/Mates with M5 | Pcs |
| RWD-62236 | Injector-Double/O.D.0.30mm-30G/C.C3.0/Mates with M5 | Pcs |
| RWD-62237 | Injector-Double/O.D.0.41mm-27G/C.C0.8/Mates with M3.5 | Pcs |
| RWD-62238 | Injector-Double/O.D.0.41mm-27G/C.C1.0/Mates with M3.5 | Pcs |
| RWD-62239 | Injector-Double/O.D.0.41mm-27G/C.C1.2/Mates with M3.5 | Pcs |
| RWD-62240 | Injector-Double/O.D.0.41mm-27G/C.C1.3/Mates with M3.5 | Pcs |
| RWD-62241 | Injector-Double/O.D.0.41mm-27G/C.C1.4/Mates with M3.5 | Pcs |
| RWD-62242 | Injector-Double/O.D.0.41mm-27G/C.C1.5/Mates with M3.5 | Pcs |
| RWD-62243 | Injector-Double/O.D.0.41mm-27G/C.C1.8/Mates with M3.5 | Pcs |
| RWD-62244 | Injector-Double/O.D.0.41mm-27G/C.C2.0/Mates with M5 | Pcs |
| RWD-62245 | Injector-Double/O.D.0.41mm-27G/C.C2.2/Mates with M5 | Pcs |
| RWD-62246 | Injector-Double/O.D.0.41mm-27G/C.C2.4/Mates with M5 | Pcs |
| RWD-62247 | Injector-Double/O.D.0.41mm-27G/C.C2.5/Mates with M5 | Pcs |
| RWD-62248 | Injector-Double/O.D.0.41mm-27G/C.C2.8/Mates with M5 | Pcs |
| RWD-62249 | Injector-Double/O.D.0.41mm-27G/C.C3.0/Mates with M5 | Pcs |
| RWD-62263 | Injector-Double/O.D.0.21mm-33G/C.C0.8/Mates with M3.5 | Pcs |
| RWD-62264 | Injector-Double/O.D.0.21mm-33G/C.C1.0/Mates with M3.5 | Pcs |
| RWD-62265 | Injector-Double/O.D.0.21mm-33G/C.C1.2/Mates with M3.5 | Pcs |
| RWD-62266 | Injector-Double/O.D.0.21mm-33G/C.C1.3/Mates with M3.5 | Pcs |
| RWD-62267 | Injector-Double/O.D.0.21mm-33G/C.C1.4/Mates with M3.5 | Pcs |
| RWD-62268 | Injector-Double/O.D.0.21mm-33G/C.C1.5/Mates with M3.5 | Pcs |
| RWD-62269 | Injector-Double/O.D.0.21mm-33G/C.C1.6/Mates with M3.5 | Pcs |
| RWD-62270 | Injector-Double/O.D.0.21mm-33G/C.C1.8/Mates with M3.5 | Pcs |
| RWD-62271 | Injector-Double/O.D.0.21mm-33G/C.C2.0/Mates with M3.5 | Pcs |
| RWD-62250 | Injector-Double/O.D.0.30mm-30G/C.C0.7/Mates with M3.5 | Pcs |
| RWD-62251 | Injector-Double/O.D.0.21mm-33G/C.C0.7/Mates with M3.5 | Pcs |
| RWD-62501 | Fixing Screw -Single/O.D.5.5mm/L7.5mm/M3.5 | Pcs |
| RWD-62502 | Fixing Screw -Single/O.D.5.5mm/L7.0mm/M3.5 | Pcs |
| RWD-62521 | Fixing Screw-Double/O.D.5.5mm/L7.5mm/M3.5 | Pcs |
| RWD-62522 | Fixing Screw-Double/O.D.7.0mm/L7.5mm/M5 | Pcs |
| RWD-62523 | Cap-Double/O.D.5.5mm/L7.0mm/M3.5 | Pcs |
| RWD-62524 | Cap-Double/O.D.7.0mm/L7.5mm/M5 | Pcs |
| RWD-62525 | Dust Cap(Alu)-Double/O.D.5.5mm/L7.0mm/M3.5 | Pcs |
| RWD-62513 | Screws-M1.0xL2.0mm (100/pkg) | Pkg |
| RWD-62514 | Screws-M1.2xL2.0mm (100/pkg) | Pkg |
| RWD-62515 | Screws-M1.4xL2.5mm (100/pkg) | Pkg |
How It Works
The double cannula system operates through precision stereotaxic implantation of bilateral guide cannulas that provide permanent access to paired brain regions. The guide cannulas feature a fixed center-to-center distance that maintains precise bilateral targeting throughout chronic experiments. Dummy cannulas seal the guides between experimental sessions, preventing tissue infiltration and maintaining patency.
During infusion procedures, internal cannulas are inserted through the guide system to deliver precise volumes to target sites. The 26G internal diameter provides sufficient flow rates for most pharmacological agents while minimizing tissue displacement. The standardized base height and mounting screw configuration ensure secure attachment to skull bone and compatibility with stereotaxic positioning systems.
The bilateral design enables simultaneous or sequential delivery to paired anatomical targets, supporting experimental designs requiring comparison between hemispheres or synchronized bilateral manipulation of neural circuits.
Features & Benefits
outer_diameter_options
- 0.41mm (27G), 0.48mm (26G), 0.64mm (23G)
center_to_center_distance_range
- 0.5mm to 3.0mm
base_height
- 7.8mm (standard), 5.5mm (mice)
mounting_screw_size
- M3.5, M5
cannula_type
- Double cannula system
administration_method
- Unilateral intracranial
system_components
- ['Guide cannula', 'Dummy cannula', 'Internal cannula', 'Fixing screw']
customization_available
- Yes, based on experimental requirements
Automation Level
- manual
Species
- Mouse
- Rat
Research Domain
- Addiction Research
- Anxiety and Depression
- Behavioral Pharmacology
- Learning and Memory
- Motor Function
- Neuroscience
- Pain Research
Brand
- RWD
Weight
- 8.27 kg
Dimensions
- L: 34.0 mm
- W: 39.0 mm
- H: 33.0 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Center-to-Center Distance Options | 12 precise distances from 0.5-2.2mm in 0.1-0.2mm increments | Fewer spacing options with larger increments | Enables precise targeting of diverse bilateral brain regions without custom manufacturing delays. |
| Cannula Gauge Size | 26G (0.48mm) outer diameter | Varies from 23G-28G depending on application | Balances minimal tissue damage with reliable drug delivery and reduced clogging risk. |
| Base Height Options | 7.8mm (rats) and 5.5mm (mice) configurations | Single height option requiring spacers or modifications | Species-optimized clearance eliminates need for additional hardware or modifications. |
| System Completeness | Complete system with guide, dummy, internal cannulas, and screws | Components sold separately requiring multiple orders | Reduces procurement complexity and ensures component compatibility for immediate use. |
| Mounting Hardware | M3.5 and M5 screw options included | Single screw size with limited compatibility | Accommodates different stereotaxic systems without requiring additional hardware sourcing. |
The Double Cannula System Pack provides comprehensive bilateral targeting capabilities with precise spacing options, species-optimized configurations, and complete component integration. The system offers 12 center-to-center distances and dual base height options for versatile experimental applications across rodent models.
Practical Tips
Verify center-to-center distance measurement under magnification before implantation to ensure accuracy.
Why: Confirms proper manufacturing tolerances and prevents targeting errors in bilateral studies.
Clean dummy cannulas with appropriate solvents between sessions and inspect for blockages.
Why: Maintains cannula patency and prevents tissue infiltration that could compromise chronic access.
Mark internal cannula insertion depth to ensure consistent bilateral penetration across sessions.
Why: Standardizes drug delivery location and improves experimental reproducibility.
If resistance is encountered during internal cannula insertion, do not force; inspect for blockage or tissue growth.
Why: Prevents cannula damage and ensures accurate drug delivery to target sites.
Record actual infusion volumes and times for each cannula to verify bilateral symmetry in delivery.
Why: Documents dosing accuracy and identifies potential unilateral delivery issues affecting data interpretation.
Use appropriate sharps disposal for all cannula components and handle with forceps to prevent needlestick injuries.
Why: Prevents injury from sharp cannula tips and maintains sterile handling procedures.
Perform bilateral histological verification of cannula placement at experiment completion.
Why: Confirms accurate targeting and enables exclusion of subjects with improper placement from data analysis.
Store sterile cannulas in individual containers to prevent damage and contamination.
Why: Preserves sterility and prevents physical damage that could affect performance during implantation.
Setup Guide
What’s in the Box
- Double guide cannula assembly (specified center-to-center distance)
- Bilateral dummy cannulas
- Bilateral internal cannulas
- Fixing screws (M3.5 or M5)
- Installation instructions (typical)
- Sterilization guidelines (typical)
Warranty
ConductScience provides a one-year warranty covering manufacturing defects and material quality. Technical support includes installation guidance, troubleshooting assistance, and custom configuration consultations for specialized research applications.
Compliance
References
Background reading relevant to this product:
What center-to-center distances are available for targeting specific bilateral brain regions?
The system offers center-to-center distances from 0.5mm to 2.2mm in precise increments: 0.5, 0.6, 0.8, 1.0, 1.2, 1.3, 1.4, 1.5, 1.6, 1.8, 2.0, and 2.2mm to accommodate various bilateral targets.
How do I determine the appropriate base height for my species?
Use 7.8mm base height for rats and 5.5mm base height for mice. The base height ensures proper clearance above the skull surface while maintaining secure attachment.
What internal cannula projection length should I specify for my target depth?
Internal cannula length depends on your specific target coordinates and guide cannula positioning. Custom lengths can be specified based on your stereotaxic calculations.
Can the system be used with standard injection pumps and tubing?
Yes, the 26G internal cannulas are compatible with standard microinjection pumps and PE tubing commonly used in neuroscience research.
What sterilization methods are recommended for the cannula components?
Components can be sterilized using autoclave, ethylene oxide, or gamma irradiation. Verify material compatibility with your preferred sterilization method.
How long can the cannulas remain implanted for chronic studies?
Implantation duration depends on experimental design and animal care protocols. Typical chronic studies maintain cannulas for weeks to months with proper care and dummy cannula maintenance.
Are custom center-to-center distances available beyond the standard options?
Yes, custom configurations can be manufactured based on specific experimental requirements. Contact for custom spacing and specification options.
What mounting screw size should I choose for my stereotaxic system?
M3.5 screws are standard for most applications, while M5 screws are available for systems requiring larger mounting hardware. Verify compatibility with your stereotaxic equipment.
Have a question about this product?