Industrial Online Meter
Multi-parameter online water quality controller measuring pH, residual chlorine, and hypochlorous acid with automatic temperature compensation and industrial communication protocols for continuous process monitoring.
| Product Name: | Industry online residual chlorine/pH controller |
| Measure range & Accuracy | 0-14 (pH) ±0.02pH |
| Hypochloric acid: | 0-20ppm ±0.01mg/L |
| Residual chlorine: | 0-10ppm ±0.01mg/L |
| Resolution: | 0.01pH, 0.01mg/L(residual chlorine),0.001mg/L(HOCL) |
| Input Resistance: | â¥1x10 ¹²Ω |
The Industrial Online Meter (Model CS-LH-IND009) is a multi-parameter water quality monitoring instrument designed for continuous industrial process control. This online controller simultaneously measures pH (0-14), residual chlorine (0-10 ppm), and hypochlorous acid (0-20 ppm) with high-precision sensors and automatic temperature compensation from 0-60°C.
The instrument features a large LCD display with English menu operation, providing real-time readouts of all parameters with configurable alarm thresholds. Built-in data logging capabilities store up to 50 measurements, while RS-485 communication with MODBUS protocol enables integration into industrial control systems. The 4-20mA current output provides analog signaling for process control applications, making this meter suitable for automated water treatment monitoring in industrial facilities.
How It Works
The Industrial Online Meter employs electrochemical sensors to simultaneously measure multiple water quality parameters. pH measurement utilizes a combination electrode that generates a millivolt potential proportional to hydrogen ion activity, with automatic temperature compensation correcting for thermal effects on electrode response. The instrument's high input resistance (≥1×10¹²Ω) minimizes measurement errors in high-purity water applications.
Residual chlorine and hypochlorous acid detection typically employ amperometric sensors that generate current proportional to oxidant concentration. The controller's microprocessor-based design provides continuous data acquisition, automatic temperature compensation, and configurable alarm outputs. Built-in signal conditioning converts sensor outputs to standardized 4-20mA current loops for process control integration.
The MODBUS communication protocol enables remote monitoring and data logging through industrial networks. Watchdog circuitry prevents system lockup, while power-down protection maintains calibration data and settings for over 10 years without external power.
Features & Benefits
Product Name:
- Industry online residual chlorine/pH controller
Measure range & Accuracy
- 0-14 (pH) ±0.02pH
Hypochloric acid:
- 0-20ppm ±0.01mg/L
Residual chlorine:
- 0-10ppm ±0.01mg/L
Resolution:
- 0.01pH, 0.01mg/L(residual chlorine),0.001mg/L(HOCL)
Input Resistance:
- â¥1x10 ¹²Ω
Temp Compensation:
- Manual / Auto temperature compensation
Communication:
- RS485, standard Modbus
Signal output:
- 4-20mA output, Maximum loop 750Ω, 0.01%FS
Power supply:
- 220V AC 10%,50/60Hzz
Hole size
- 91x91mm
Automation Level
- semi-automated
Brand
- ConductScience
Size
- 96x96x115mm
Weight
- 0.9KG
Research Domain
- Analytical Chemistry
- Environmental Monitoring
- Food Science
- Industrial Hygiene
- Microbiology
- Pharmaceutical QC
Weight
- 1.98 kg
Dimensions
- L: 4.53 mm
- W: 3.78 mm
- H: 3.78 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Parameter Range | pH 0-14, residual chlorine 0-10 ppm, hypochlorous acid 0-20 ppm | Single-parameter units or basic dual-parameter systems with limited ranges | Comprehensive water quality assessment reduces installation complexity and provides complete chemical monitoring in one unit |
| Display and Interface | Large LCD with multi-parameter display and English menu operation | Simple LED displays or basic digital readouts | Simultaneous parameter viewing and intuitive menu navigation improves operator efficiency and reduces training requirements |
| Communication Capability | RS-485 MODBUS protocol with 4-20mA output | Basic analog outputs without digital communication | Dual communication modes enable both legacy analog systems and modern digital networks for flexible integration |
| Data Storage | 50-measurement internal memory | No internal storage requiring external data logging | Local data retention provides backup during communication failures and enables historical review without external systems |
| Temperature Compensation | Automatic compensation 0-60°C for all parameters | Manual compensation or limited temperature range coverage | Maintains measurement accuracy across typical industrial temperature ranges without operator intervention |
This integrated multi-parameter meter combines comprehensive measurement capability with industrial communication protocols and local data storage. The combination of automatic temperature compensation, alarm management, and dual-mode communication provides a complete process monitoring solution suitable for demanding industrial applications.
Practical Tips
Perform pH calibration using fresh buffer solutions at process temperature when possible.
Why: Temperature-matched calibration improves accuracy by minimizing thermal effects on electrode response.
Clean sensor electrodes weekly with appropriate cleaning solutions to prevent fouling buildup.
Why: Regular cleaning maintains sensor sensitivity and prevents drift caused by coating or contamination.
Set alarm hysteresis to 5-10% of the alarm setpoint to prevent relay chatter.
Why: Proper hysteresis prevents nuisance alarms during normal process fluctuations near threshold values.
Check sensor cable connections if readings become erratic or drift excessively.
Why: Loose or corroded connections can introduce electrical noise and cause unstable measurements.
Monitor temperature compensation effectiveness by comparing manual and automatic readings periodically.
Why: Verification ensures temperature compensation algorithms are functioning correctly across the operating range.
Install proper electrical grounding and ensure NEMA-rated enclosures in wet industrial environments.
Why: Electrical safety prevents shock hazards and protects electronic components from moisture damage.
Store spare calibration standards in cool, dark locations and replace according to expiration dates.
Why: Fresh standards ensure calibration accuracy and prevent measurement bias from degraded reference materials.
Document all calibration activities and alarm events in a maintenance log for trend analysis.
Why: Historical records help identify patterns in sensor performance and optimize maintenance schedules.
Setup Guide
What’s in the Box
- Industrial Online Meter main unit
- Power connection terminals and hardware
- Panel mounting bracket and screws
- User manual and quick start guide
- RS-485 communication cable (typical)
- Sensor connection cables (typical)
- Calibration certificate (typical)
Warranty
ConductScience provides a one-year manufacturer warranty covering defects in materials and workmanship. Technical support includes calibration guidance and troubleshooting assistance for optimal performance in industrial monitoring applications.
Compliance
References
Background reading relevant to this product:
What is the recommended calibration frequency for the pH and chlorine sensors?
Calibration frequency depends on application criticality and water matrix. For most industrial applications, monthly pH calibration with certified buffers and bi-weekly chlorine verification with DPD standards maintains accuracy within specifications.
Can the meter handle high-purity water applications with low ionic strength?
Yes, the high input resistance (≥1×10¹²Ω) minimizes measurement errors in low-conductivity water. However, pH response may be slower in ultra-pure water due to reduced ionic strength.
What sensor maintenance is required for continuous operation?
Regular sensor cleaning and junction maintenance prevent fouling-related drift. pH electrode storage solution should be maintained, and chlorine sensor membranes require periodic replacement based on usage intensity.
How does temperature compensation affect measurement accuracy?
Automatic temperature compensation corrects pH readings for thermal effects on electrode slope and zero point. Chlorine measurements may also benefit from temperature correction depending on sensor type and measurement method.
What data formats are available through the MODBUS interface?
Consult product datasheet for specific MODBUS register mapping and data formats. Standard implementations typically provide real-time measurements, alarm status, and configuration parameters as 16-bit registers.
Can multiple meters be networked on a single RS-485 bus?
Yes, RS-485 supports multi-drop networking with unique device addresses. Up to 32 devices can typically share a single bus with proper termination and addressing configuration.
What is the response time for alarm outputs during process upsets?
Response time depends on sensor characteristics and measurement averaging. Consult product datasheet for specific response times, which are typically optimized for process control applications requiring rapid alarm notification.
How does this meter compare to laboratory-grade analytical instruments?
This online process meter prioritizes continuous operation and process integration over laboratory precision. While accuracy is suitable for process control, laboratory instruments may offer higher precision for research applications requiring traceable measurements.
Have a question about this product?