ConductVision Materials Science

Paint & coating image analysis.

Measure layer thickness, porosity, pore size, coverage, and indentation dimensions from calibrated cross-section and surface images.

Available as a configurable Paint Measurement workflow in ConductImage.

Illustrative unprocessed coating cross-section prepared for thickness and porosity analysisRepresentative input specimen

Start with the image

Provide a calibrated cross-section or surface image and the measurement question your team needs to answer.

Single image or folder
Calibrated real units
Reviewable masks
CSV and annotated exports

One coating, four measurement questions

Keep the image, measurement, and review evidence together.

Choose the measurement that matches the specimen and the decision. These synthetic specimen visuals show the analysis intent; each result stays linked to its source image and overlay so your team can inspect how it was produced.

Synthetic coating cross-section with traced upper and lower boundaries and repeated thickness measurements
01Profile + statistics

Layer thickness

Trace the upper and lower coating boundaries, then report each thickness point with mean, standard deviation, minimum, maximum, and percentiles.

Synthetic coating cross-section with an ROI boundary and highlighted pores of varied sizes
02Mask + histogram

Porosity and pore size

Segment pores inside the eligible coating area, then report pore count, total pore area, porosity percentage, and size distribution.

Synthetic top-down coated coupon with a coverage overlay and highlighted uncovered holidays
03Coverage + location map

Coverage and holidays

Measure coated versus uncovered area on surface images and locate voids, holidays, or thin regions for review.

Synthetic Vickers indentation micrograph with measured horizontal and vertical diagonals
04Dimensions + marked image

Indentation dimensions

Measure Vickers indentation diagonals and export dimensioned images when the image scale and test inputs are available.

See what the software returns

Move from a cross-section to reviewable evidence.

Explore the result views for thickness, porosity, and processed-image review. The examples use synthetic imagery and illustrative overlays, not customer data.

Privacy-safe examples

Paint Results

Explore illustrative ConductImage outputs

Synthetic coating cross-section with an illustrative analysis overlay
ROI boundaryMeasurement points

Each point records X position, upper bound Y0, lower bound Y1, and the resulting thickness.

Mean + SD
Median
Min + max
D10 / D50 / D90

Thickness distribution

Adjustable histogram bins

Illustrative
Measurement intervalfit when valid

The fitted normal curve is shown only when the observed distribution is reasonably close to normal.

Illustrative synthetic images and overlays. Final fields and model options depend on the configured protocol.
Synthetic Vickers indentation illustration with measured horizontal and vertical diagonals
Illustrative indentation measurement

Supporting dimension workflow

Keep a dimensioned indentation image with the record.

Measure the horizontal and vertical Vickers diagonals from a calibrated image and retain the annotated frame for review or export.

This supports indentation dimensioning. A validated hardness calculation requires the applicable load, calibration, test method, and protocol validation.

The ConductImage workflow

Configure once. Review every image.

A protocol records the image source, selected model, calibration, and analysis settings. Run it on one image or a folder, then inspect the results before export.

  1. 1

    Load and preview

    Choose one image or a folder, preview the selection, and navigate the images in a batch.

  2. 2

    Select the model and scale

    Choose an available model, calibrate from a scale bar or known feature, and confirm the coating region.

  3. 3

    Segment and review

    Run the configured model, inspect the layer and pore overlays, and adjust the protocol when needed.

  4. 4

    Compare and export

    Review tables, distributions, source-result pairs, protocol settings, and annotated frames.

Complete software feature map

The documented Paint Measurement controls, in one place.

01

Image and folder intake

Open one image or an image folder, preview the selection, and move through every frame in the batch.

02

Model and protocol selection

Choose an available analysis model and retain the protocol parameters used for each calculation.

03

Point-level thickness

Inspect the X position, upper boundary Y0, lower boundary Y1, and calculated thickness at each point.

04

Porosity details

Review pore count, eligible ROI area, total pore area, porosity percentage, and pore-area details by image.

05

Synchronized image review

Filter ROI, porosity, or all results; pan, zoom, reset, and synchronize the source and processed views.

06

Distribution controls

Change histogram bin width and add a normal-curve overlay only when the observed distribution supports it.

Reported outputs

Statistics your team can trace back to the frame.

Thickness
Mean, standard deviation, median, minimum, maximum, D10, D50, and D90
Porosity
Pore count, eligible ROI area, total pore area, and porosity percentage
Density context
Image-based solid-area comparison derived from the segmented porosity result, not direct bulk density
Distributions
Thickness and pore-area histograms with configurable bin width and conditional normal-curve overlay
Review images
Filtered source and result views with synchronized pan, zoom, and reset controls
Traceability
Selected model, protocol parameters, calibration, per-point bounds, and image-linked results

What to send

Start with representative images and a measurement goal.

  • Representative images that include the coating and the boundaries you need to measure.
  • A scale bar, pixel calibration, or known reference dimension when results need real units.
  • The samples, lots, locations, or conditions that need to be compared.
  • Your accepted manual or instrument method for validation and review.

Cross-section measurements describe the imaged plane. Bulk density, whole-part porosity, adhesion, and service life require their own reference tests.

Industrial applications

Built for coatings your lab already sections and photographs.

Automotive paint

Compare primer, basecoat, and clearcoat thickness with pore and coverage findings across panels or lots.

Thermal spray coatings

Measure layer thickness and pore area on polished cross-sections while keeping every result tied to its field.

Powder coatings

Review finished-layer uniformity, thin regions, pores, and surface coverage across representative images.

PCB conformal coatings

Locate uncovered areas and compare coating coverage around traces, pads, and component boundaries.

Send a paint or coating image and a measurement goal

We will match it to the closest ConductVision workflow and identify what needs custom validation for your images.