48MP 1080P Hdmi USB Electron Video Digital Microscope Camera with Cantilever Foldable Stand Holder Bracket
48MP digital microscope camera with HDMI/USB dual output, 5X-100X magnification range, and cantilever foldable stand for versatile imaging applications.
| Automation Level | semi-automated |
| Product Type | Microscope |
| Microscope Type | Digital |
| Application | General Laboratory |
| Skill Level | Entry Level |
| Brand | ConductScience |
The MCX-0029 is a 48MP digital microscope camera system featuring dual HDMI/USB output capabilities and a cantilever foldable stand. The system incorporates a 1/3 inch 48MP sensor with 1.335µm pixel pitch, providing 1920×1080 HDMI resolution for real-time imaging applications. The monocular configuration includes a 0.7X-4.5X objective with 1:6.4 zoom ratio, delivering 5X-100X total magnification when paired with a 10.1-inch display.
The system features standard C-mount interface compatibility with included 0.5X adapter lens, enabling integration with existing optical setups. LED ring illumination provides consistent sample lighting, while the adjustable working distance of 20mm-1000mm accommodates diverse specimen geometries. The cantilever stand design allows for flexible positioning and space-efficient laboratory integration.
How It Works
The system operates through digital image capture using a 48MP CMOS sensor with 1.335µm pixel dimensions. Incident illumination from the LED ring light reflects off the specimen surface, with reflected light collected through the 0.7X-4.5X objective lens system. The optical path includes a standard C-mount interface with 0.5X adapter lens for field of view optimization.
Digital image processing converts the optical signal to electronic format, with simultaneous HDMI and USB output streams. The HDMI output provides 1920×1080 resolution for real-time display, while USB connectivity enables direct computer interface for image capture and analysis software integration. The pole focusing mechanism allows precise focal plane adjustment across the 20mm-1000mm working distance range.
The cantilever stand geometry provides mechanical stability while maintaining specimen access. The foldable design enables compact storage and transport, with the stand supporting the optical assembly above the specimen plane. Total system magnification results from the combination of objective magnification, adapter lens factor, and display characteristics.
Features & Benefits
Automation Level
- semi-automated
Product Type
- Microscope
Microscope Type
- Digital
Application
- General Laboratory
Skill Level
- Entry Level
Brand
- ConductScience
Research Domain
- Analytical Chemistry
- Environmental Monitoring
- Food Science
- Industrial Hygiene
- Materials Science
- Microbiology
- Pharmaceutical QC
Weight
- 0.25 kg
Dimensions
- L: 4.9 mm
- W: 6.6 mm
- H: 6.6 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Sensor Resolution | 48MP CMOS sensor with 1.335µm pixels | Entry-level units often provide 2-8MP resolution with larger pixel dimensions | Higher pixel count enables greater detail capture for documentation and analysis applications. |
| Output Options | Dual HDMI/USB output capability | Basic models typically offer USB-only connectivity | Simultaneous real-time display and computer capture improves workflow efficiency in laboratory settings. |
| Magnification Range | 0.7X-4.5X objective with 5X-100X total magnification | Fixed magnification systems require lens changes for different viewing ranges | Continuous zoom adjustment eliminates lens changing and enables rapid field of view optimization. |
| Working Distance | 20mm-1000mm adjustable working distance | Compact systems often limit working distance to under 100mm | Extended working distance accommodates larger specimens and reduces mechanical interference during manipulation. |
| Stand Design | Cantilever foldable stand with space-efficient geometry | Traditional boom stands require larger desk footprint | Compact design maximizes available workspace while maintaining mechanical stability for precise imaging. |
| Interface Compatibility | Standard C-mount with included 0.5X adapter | Proprietary lens mounts limit accessory options | Industry-standard mounting enables integration with existing optical components and future system expansion. |
The system combines high-resolution 48MP imaging with flexible dual-output connectivity in a space-efficient cantilever design. The standard C-mount interface and extended working distance range provide versatility for diverse laboratory imaging applications.
Practical Tips
Use a stage micrometer with known dimensions to calibrate measurement accuracy at each magnification setting before quantitative analysis.
Why: Optical magnification can vary slightly across the zoom range, affecting measurement precision.
Clean optical surfaces weekly using lens cleaning solution and lint-free wipes, working from center to edge in circular motions.
Why: Dust and fingerprints on lenses significantly degrade image quality and contrast.
Position specimens on a neutral background and adjust LED intensity to prevent overexposure of reflective surfaces.
Why: Proper lighting eliminates hot spots and ensures even illumination for accurate color representation.
Set working distance to mid-range (300-500mm) initially, then adjust magnification before fine-tuning focus for optimal image quality.
Why: This sequence minimizes focus hunting and provides stable imaging geometry.
If USB connection is unstable, try different USB ports or use a powered USB hub to ensure adequate power delivery to the camera.
Why: High-resolution cameras require consistent power and data bandwidth for reliable operation.
Capture multiple images at slightly different focus positions for specimens with significant depth variation.
Why: Focus stacking can be performed in post-processing to extend depth of field beyond the optical limit.
Ensure cantilever stand is securely positioned on a stable surface before adjusting camera height or position.
Why: Unstable mounting can result in equipment damage or specimen contamination from unexpected movement.
Fold and store the cantilever stand in its collapsed position when not in use to prevent dust accumulation and mechanical stress.
Why: Proper storage maintains optical alignment and extends mechanical component lifetime.
Setup Guide
What’s in the Box
- 48MP HDMI/USB microscope camera assembly
- Cantilever foldable stand with mounting hardware
- 0.5X adapter lens
- LED ring light illumination system
- HDMI cable (typical)
- USB cable (typical)
- Power adapter (typical)
- User manual and software CD (typical)
Compliance
References
Background reading relevant to this product:
Warranty & ConductCare
ConductScience provides a one-year manufacturer warranty covering defects in materials and workmanship, with technical support for setup, calibration, and operational assistance.
What image file formats are supported for data export?
Consult product datasheet for supported file formats. USB connectivity typically enables standard image formats through computer-based capture software.
Can the system be calibrated for quantitative measurements?
The system supports dimensional calibration using stage micrometers or calibration standards appropriate for the working magnification range.
Is the LED illumination intensity adjustable?
Yes, the LED ring light system includes intensity adjustment controls for optimizing illumination conditions across different specimen types.
What is the maximum specimen thickness that can be accommodated?
The 20mm minimum working distance limits specimen thickness, though the cantilever design allows some flexibility in positioning larger samples.
Does the system include measurement and annotation software?
Consult product datasheet for included software. USB connectivity enables integration with third-party image analysis and measurement applications.
How does the 48MP sensor resolution translate to actual image quality?
The 48MP sensor provides high pixel density for detail capture, though actual resolution depends on optical magnification and specimen contrast.
Can additional objective lenses be mounted to the C-mount interface?
Yes, the standard C-mount interface accepts compatible objective lenses, though working distance and illumination may require adjustment.
What maintenance is required for the optical components?
Regular cleaning of lens surfaces with appropriate solvents and lint-free materials maintains optical performance. LED components typically require no routine maintenance.
Have a question about this product?
Accessories
Enhance your setup with compatible accessories
Frequently Bought Together
Upgrade Options
Related Products