Semiconductor, packaging & electronics

Thin-film step coverage & uniformity

Quantify layer thickness and step coverage across planar and topographic semiconductor features.

ModalitiesCross-section SEMOptical microscopyEllipsometry map
Illustrative multilayer thin-film cross-section over a stepped semiconductor feature
42 nm
Planar film
78%
Step coverage
18
Sections

Example outputs shown for illustration. Numbers depend on your samples and protocol.

Image: Illustrative rendering (AI-generated, gpt-image-2), not a cross-section of a specific device

Cross-section SEM
Nanometre-scale layer thickness and sidewall geometry at defined features.
Optical microscopy
Wider-field coverage and uniformity screening across many locations quickly.
Ellipsometry map
Non-destructive planar film thickness sampled across the wafer surface.

Results

Compare conformality and local thinning across a defined wafer, device, or coupon sampling plan before process-development review.

nm or µm

Local layer thickness

Perpendicular distance between the defined layer interfaces at each accepted sampling point.

Sample distributionmedian 42 nm

Example, not a claimed result

In your report: Per-point table, median, P5/P95, minimum, maximum, and location identifier.

%

Step coverage

Local thickness at the sidewall or feature bottom divided by the agreed reference thickness on the field, multiplied by 100.

Sidewall coverage78%
Bottom
64%
Corner
71%

Example, not a claimed result

In your report: Per-feature coverage, distribution, and annotated reference locations.

% area

Void area fraction

Segmented void area divided by the eligible coating or fill area in the two-dimensional cross-section.

Void area fraction1.4%
<1µm
1-2µm
2-4µm
>4µm

Example, not a claimed result

In your report: Per-field value, void-size distribution, and mask overlay. This is not a three-dimensional void volume fraction.

% length

Interface continuity

Length of visible interface meeting the agreed continuity rule divided by the eligible interface length.

Continuous length96%
ContinuousGaps found

Example, not a claimed result

In your report: Continuity value, gap locations, and the rule version used to classify a gap.

Built around your image set

Use the calibrated images your team already collects, together with the locations you need to compare.

01
Representative cross-sections
Provide polished, representative cross-sections with a recorded scale calibration and the field, sidewall, and bottom regions visible.
02
Image capture details
Record instrument, magnification, pixel scale, coating stack, preparation method, and the smallest feature the review must resolve.
03
Locations to compare
State the locations, number of sections, and process conditions to compare. A field of view is not treated as a wafer-wide result by itself.

Each report includes

The artifacts your team receives, ready for review and archive.

Annotated image set

Original images with regions of interest, measurement points, masks, and finding overlays.

Measurement table

Location-indexed values, units, distributions, and QC flags in a structured export.

Method record

Calibration evidence, analysis settings, version history, and validation summary.

Confidence in every resultTraceable measurements, reviewed against your agreed reference method.
Traceable scale
The report records the image scale, calibration evidence, and the method-specific expanded measurement uncertainty. It does not use one product-wide accuracy number.
Reference comparison
The configured method is compared with the customer’s accepted reference method or reviewed annotations and reports bias by thickness range and image condition.
Detection performance
Void and gap findings are evaluated against reviewed reference regions with precision, recall, and segmentation overlap, separated by the conditions that affect performance.
Repeatability
The locked protocol is rerun on the same inputs and on a defined repeat set. The review records variation caused by image acquisition, sampling, and analysis separately where possible.

What this result does not establish: Measures visible layer boundaries in supplied images. Material identity, optical-model choices, and calibrated thickness acceptance remain with your metrology method.

The measurement, today

Film thickness is often reported as one number from a monitor wafer, while local coverage around steps, vias, and corners is inspected separately and qualitatively.

What it costs

Non-uniform coverage can affect isolation, barriers, contacts, and subsequent etch behavior. A spatial measurement set exposes where a stack departs from its intended geometry.

From image to reviewed result

  1. 1

    Load the layer images

    Provide calibrated cross-section or thickness-map images from the surfaces and topography under review.

  2. 2

    Separate the stack

    Trace each visible layer and the feature geometry beneath it.

  3. 3

    Measure coverage

    Compare local layer thickness at the top, sidewall, and bottom of configured features.

  4. 4

    Export the profile

    Review thickness distributions, minimum locations, and annotated cross-sections together.

Thin-film step coverage and uniformity measurement

Step coverage describes how conformally a deposited film follows the topography of a feature: how thickness at a sidewall or feature bottom compares with thickness on the open field. ConductVision measures it directly from cross-section SEM, optical microscopy, and ellipsometry map images, so conformality, local thinning, and film thickness uniformity are quantified per location instead of inferred from a single monitor-wafer number.

Each engagement returns per-location layer thickness, step coverage percentage, void area fraction, and interface continuity, with every value tied back to the annotated image it came from. Results are compared against your accepted reference method and reported with method-specific measurement uncertainty, not a product-wide accuracy claim.

Common questions this answers

  • Is the film conformal around vias, trenches, and corners?
  • Where is the film thinnest, and by how much?
  • How does step coverage compare across recipes, wafers, or lots?
  • Are there voids or interface gaps in the deposited stack?

Related measurements: etch profile metrology, CMP scratch and planarization inspection, coating thickness and porosity.

Talk to a scientist

Not sure this is the right measurement?

Send a representative image and your measurement goal. A ConductVision scientist will confirm whether this is the right fit, or point you to the closer workflow, before you commit to a quote.

Share your image set
One representative image is enough to start the conversation.
Book a 30-minute review
Walk through the measurement plan and confidence evidence live.

Send a sample image and a measurement goal

We will show the closest ConductVision workflow and flag what needs custom validation for your images.