ConductVision

Validated across twelve public benchmarks.

Compare ConductVision against published tracking software and human raters across open behavioral video and microscopy datasets before running a study on your own recordings.

Validated benchmarks
12

9 behavioral assays and 3 microscopy test suites

Frames and fields scored
4.6M+

Held-out public recordings and annotated image sets

Organisms and modalities
5

Mouse, rat, zebrafish, Drosophila and stained tissue

Flexible execution
CPU + GPU

Browser upload or local workstation inference

ConductVision + 95% CIPublished software and raters

Rodent mazes and arena exploration

Zone dwell time, compartment transitions, locomotor distance and exploratory head dips measured frame by frame against published pose trackers and commercial arena software.

3 validated suites
01Mouse · 20 videosMatches DeepLabCut and EthoVisionLive in browser and desktop

Open Field Test

Across 20 public mouse recordings totaling 304,634 frames, ConductVision matches DeepLabCut on center dwell time and matches commercial tracking on cohort distance spread.

r = 0.9983
Center-zone time correlation
1.20 s median difference across 20 mice (98.88% frame-zone agreement)
Open-field endpoint correlation and frame agreement

Agreement against published reference tracking across 20 mice (0 to 1 scale, higher is closer)

Body within 40 px (cloud pose) 0.9989
Center-zone dwell time (r) 0.9983
Frame-by-frame zone match 0.9888
Total distance traveled (r) 0.9418
Execution: Real-time in browser and desktop · 99.89% of frames localized within 40 px

Individual assay endpoints

3 measured metrics
EndpointScoreBenchmark detail
Time in center zoner = 0.99832.47% relative gap (1.20 s median) vs. DeepLabCut; 98.88% frame-zone agreement
Total distance traveledr = 0.9418Cohort CV 10.62% (95% CI 7.6% to 13.5%), matching EthoVision XT (11.03%) and DeepLabCut (12.24%)
Body-centroid localization4.33 pxMedian pixel distance vs. reference pose; 99.89% of frames within 40 px

Evaluated zero-shot across all 20 arena recordings using standard center-zone geometry and 25 Hz body-centroid trajectories.

Dataset: Sturman et al., Neuropsychopharmacology 2020 · 20 mouse videos (304,634 frames)

02Mouse · 24 maze + 5 rater videosAhead of EthoVision on head dipsLive in browser and desktop

Elevated Plus Maze and Head Dips

On 24 elevated plus maze recordings and 5 three-rater head-dip recordings, ConductVision matches DeepLabCut across open and closed arms while outperforming EthoVision on exploratory head dips.

r = 0.9231
Head-dip bout correlation vs. 3 raters
Ahead of EthoVision XT (r = 0.82) and level with DeepLabCut (r = 0.92)
Head-dip bout correlation against 3 human raters

Pearson r vs. 3-rater consensus on held-out elevated plus maze videos (0.5 to 1.0 scale)

ConductVision 0.9231
DeepLabCut (published) 0.9200
EthoVision XT (published) 0.8200
Execution: Real-time in browser and desktop · 96.89% on-maze detection (vs. DeepLabCut 97.05%)

Individual assay endpoints

6 measured metrics
EndpointScoreBenchmark detail
Open-arm dwell timer = 0.998199.61% of frames within 40 px of DeepLabCut reference centroid
Closed-arm dwell timer = 0.9965Cohort CV 37.31% (95% CI 31.1% to 43.3%) vs. EthoVision 36.26% and DeepLabCut 37.66%
Center-platform dwell timer = 0.9869Consistent arm-entry boundary timing across all 24 trials
Total maze distancer = 0.9800Cohort CV 32.13% (95% CI 25.6% to 38.6%); 96.89% on-maze frame retention
Head-dip bout countr = 0.9231Scored against 3 human raters; ahead of EthoVision XT (0.82) and tied with DeepLabCut (0.92)
Head-dip total durationr = 0.9466Agreement with 3-rater manual duration scoring across open-arm edges

Arm-occupancy metrics scored across all 24 recordings; head-dip bouts and duration scored against the mean of 3 independent human raters.

Dataset: Sturman et al., Neuropsychopharmacology 2020 · 24 EPM videos plus 5 three-rater head-dip videos

03Mouse · 32 videosMatches published reference poseLive in browser and desktop

Light/Dark Box

Across 32 mouse Light/Dark Box trials totaling 288,000 frames, ConductVision tracks bright-side occupancy, first-transition latency within a sixth of a second and compartment crossings.

r = 0.9932
Light-compartment dwell correlation
0.16 s median error on latency to first dark entry across 32 trials
Light/Dark Box endpoint correlations across 32 trials

Pearson r and frame-side agreement vs. published reference trajectories (0.9 to 1.0 scale)

Visible frames within 40 px 0.9969
Light-compartment time (r) 0.9932
Latency to first dark entry (r) 0.9920
Compartment transitions >= 1 s (r) 0.9692
Execution: Real-time in browser and desktop · 99.69% of visible frames within 40 px

Individual assay endpoints

3 measured metrics
EndpointScoreBenchmark detail
Light-compartment dwell timer = 0.993298.50% frame-by-frame compartment match; 99.69% of visible frames within 40 px
Latency to first dark entryr = 0.99200.16 s median absolute difference from first doorway crossing across 32 mice
Compartment transitions (at least 1 s)r = 0.96922.0 crossings median absolute difference per session

Transitions require at least 1.0 s sustained presence after crossing the doorway threshold to reject nose-poke flicker.

Dataset: von Ziegler et al., Nature Methods 2024 · 32 mouse videos (288,000 frames)

Behavioral ethograms and continuous home-cage scoring

Automated classification of locomotor immobility, four-behavior swim ethograms and 24-hour infrared cage activity evaluated with leave-one-subject-out cross-validation.

3 validated suites
04Mouse · 10 videos vs. 4 ratersAhead of 4 human ratersValidated local and cloud model

Mouse Forced Swim Test

Evaluated with 10-fold leave-one-video-out cross-validation across 93,368 frames, ConductVision exceeds the agreement of 4 independent human raters on both frame-level F1 and 6-minute immobility totals.

r = 0.9731
Total immobility correlation
7.33 s MAE per 6-min session vs. 27.04 s mean MAE across 4 human raters
Immobility scoring correlation vs. multi-rater consensus

10-fold leave-one-video-out Pearson r on 6-minute total immobility (0.4 to 1.0 scale)

ConductVision 0.9731
4 human raters (mean pairwise) 0.6520
Execution: 0.41 s per 6-minute video on standard CPU (878x faster than real time)

Individual assay endpoints

4 measured metrics
EndpointScoreBenchmark detail
6-minute total immobility timer = 0.9731Spearman rho = 0.9515; 7.33 s MAE vs. 27.04 s mean pairwise MAE among 4 human raters
Frame-level immobility F10.7686Precision 0.7620, recall 0.7760 across 93,368 frames (ahead of 4-rater mean F1 0.6740)
Bout-level immobility F10.7340Temporal bout segmentation across all 10 held-out recordings
Workstation CPU runtime0.41 sProcesses a complete 6-minute video in under half a second without a GPU

Strict 10-fold leave-one-video-out evaluation against majority consensus labels; zero frames from the test recording enter training.

Dataset: Sturman et al., Neuropsychopharmacology 2020 · 10 videos (93,368 frames), 4 independent human raters

05Rat · 1,008 held-out clips87.80% 4-class accuracyValidated local and cloud model

Rat Forced Swim 4-Class Ethogram

On 1,008 held-out 3-second rat swim clips, ConductVision separates passive floating from active swimming, vertical wall climbing and bottom diving at 128.2x real-time CPU speed.

87.80%
4-class behavioral accuracy
0.8754 macro F1 across immobility, swimming, climbing and diving
Per-behavior F1 across the 4-class rat swim ethogram

Held-out test F1 across 1,008 3-second clips (0.7 to 1.0 scale)

Immobility (passive floating) 0.9108
Diving (submerged descent) 0.8923
Climbing (vertical forepaw thrashing) 0.8715
Swimming (horizontal propulsion) 0.8270
Execution: 23.4 ms per 3-second clip on CPU (128.2x real-time throughput)

Individual assay endpoints

5 measured metrics
EndpointScoreBenchmark detail
Immobility F10.9108Passive posture with minimal stabilizing movement
Diving F10.8923Full head and body submersion toward cylinder base
Climbing F10.8715Upward forepaw motion along the acrylic cylinder wall
Swimming F10.8270Horizontal quadrant crossing and active paddling
Overall 4-class macro F10.875487.80% top-1 clip accuracy across 1,008 held-out clips at 128.2x real-time CPU speed

Scored on the held-out split across all four standard Detke-protocol rat swim postures without manual ROI cropping.

Dataset: Della Valle et al., 2022 · 1,008 held-out 3-second behavioral video clips

06Mouse · 431 IR recordings (3.21M frames)Ahead of published eNeuro 2025 modelValidated local and cloud model

24-Hour Home-Cage Phenotyping (ConductPheno)

Across 431 continuous infrared recordings totaling 3,210,263 frames at 25 Hz, ConductPheno classifies eight spontaneous home-cage behaviors with 10-fold leave-one-mouse-out validation.

83.81%
8-behavior frame accuracy
Ahead of published eNeuro 2025 baseline (83.60%) across C57BL/6 and SWISS mice
Overall 8-behavior home-cage accuracy across 3.21M frames

10-fold leave-one-mouse-out frame accuracy (%) alongside human inter-rater ceiling (75% to 90% scale)

Human review reference 86.40%
ConductPheno (ConductVision) 83.81%
DeepEthoProfile (eNeuro 2025) 83.60%
Execution: 32.3 FPS end-to-end on CPU (6.5x real time at 5 Hz sampling)

Individual assay endpoints

8 measured metrics
EndpointScoreBenchmark detail
RestF1 0.9449Inactive nest and sleep bouts in continuous 24-hour infrared video
HangF1 0.9431Wire-lid suspension and inverted climbing
EatF1 0.9417Food-hopper feeding bouts separated from adjacent rearing
DrinkF1 0.8703Spout licking and brief hydration visits
GroomF1 0.6878Self-grooming bouts across strains (0.7760 F1 in white SWISS mice)
RearF1 0.6748Supported and unsupported hindlimb rearing (0.7470 F1 in white SWISS mice)
MicromovementF1 0.6528In-place postural shifts and head turns without locomotion
WalkF1 0.6189Cage-floor locomotion across bedding; C57BL/6 accuracy 82.05% vs. published 80.00%

10-fold leave-one-mouse-out cross-validation so every mouse in testing is unseen; coat-color accuracy spans 82.05% on C57BL/6 and 85.57% on SWISS.

Dataset: DeepEthoProfile benchmark, eNeuro 2025 · 431 infrared clips (3,210,263 frames at 25 Hz across black C57BL/6 and white SWISS strains)

Motor coordination, aquatic toxicology and invertebrate climbing

Multi-keypoint limb tracking on rotating rods, single-fish diving trajectories across toxicology exposures and multi-vial negative geotaxis under optical stress.

3 validated suites
07Mouse · 16 unseen videos (9 + 12 keypoints)97.1% front and 97.0% back PCK@15Validated local and cloud model

Dual-View Rotarod Motor Coordination

On 16 unseen accelerating rotarod videos filmed from front and rear angles, ConductVision tracks forepaws, hindpaws, snout, ears, tail and drum edges with over 97% PCK@15.

97.14%
Front-view PCK@15 accuracy
97.02% back-view PCK@15 · 5.10 to 5.66 px median limb and body error
Dual-view rotarod keypoint accuracy (PCK@15 and PCK@10)

Percentage of predicted anatomical keypoints within 15 px and 10 px on 16 unseen videos (80% to 100% scale)

Front view (12 keypoints) PCK@15 97.14%
Back view (9 keypoints) PCK@15 97.02%
Back view (9 keypoints) PCK@10 94.04%
Front view (12 keypoints) PCK@10 90.27%
Execution: 14.2 to 15.7 FPS on CPU · 437 to 499 FPS on GPU

Individual assay endpoints

4 measured metrics
EndpointScoreBenchmark detail
Back-view pose (9 keypoints)97.02% PCK@1594.04% PCK@10, 5.10 px median error and 0.9762 occlusion visibility F1
Front-view pose (12 keypoints)97.14% PCK@1590.27% PCK@10, 5.66 px median error and 0.9766 occlusion visibility F1
Hindpaws and tail (back view)4.61 to 5.69 pxTail median error 4.61 px; left and right hindpaws 4.89 to 5.69 px; rod corners 4.70 to 5.63 px
Forepaws, snout and ears (front view)5.56 to 6.50 pxForepaws 5.58 to 5.87 px, snout 5.89 px and ear bases 5.56 to 6.50 px median error

Evaluated on held-out recordings with simultaneous sub-pixel coordinate localization and per-keypoint occlusion visibility scoring.

Dataset: Labouesse et al., 2023 · 16 unseen videos across back (9 keypoints) and front (12 keypoints) views

08Adult zebrafish · 89 toxicology trials100% recall · 1.63 px errorValidated local and cloud model

Zebrafish Novel Tank Diving

Validated across 89 environmental toxicology trials and unseen white-plastic tanks, ConductVision tracks diving depth with 1.63 px precision and reproduces published PFOS exposure shifts.

1.63 px
Median fish centroid error
100.0% detection recall · 0.0% empty-tank false positives · 93.49% unseen tank transfer
Detection, segmentation and zero-shot tank transfer

Accuracy and overlap scores across held-out toxicology and unseen STAR Protocol tanks (0 to 100% scale)

Single-fish detection recall 100.0%
Zero-shot unseen white-tank hit rate 93.49%
Fish body segmentation Dice 86.11%
Execution: 12.5 FPS on CPU · 1,199 FPS on GPU

Individual assay endpoints

4 measured metrics
EndpointScoreBenchmark detail
Detection recall and specificity100.0%100.0% occupied-frame recall with 0.0% false positives on empty tank frames
Fish centroid and mask precision1.63 pxMedian centroid localization error; 0.8611 segmentation Dice overlap
Unseen white-tank generalization93.49%Zero-shot water-column tracking on unseen STAR Protocol white plastic tanks
PFOS toxicology dose-response (89 trials)24.5% to 33.3%Reproduces top-half dwell rise (24.5% control, 25.9% at 0.1 uM, 33.3% at 1.0 uM) and latency drop (85.1 s to 73.2 s)

Zero false detections on empty-water frames; transfers zero-shot to opaque white tanks at 93.49% in-water hit rate.

Dataset: 89 adult zebrafish PFOS toxicology recordings plus unseen STAR Protocol white-tank recordings

09Drosophila · Multi-vial climbing racks0.9024 multi-vial F1Validated local and cloud model

Drosophila Negative Geotaxis (RING Climbing)

On held-out rapid iterative negative geotaxis recordings, ConductVision localizes individual climbing flies across parallel glass vials within 2 pixels and holds accuracy under lighting stress.

0.9024
Multi-vial fly detection F1
94.83% precision · 2.03 px centroid MAE · holds 0.897 to 0.901 under glare and dim light
Multi-vial fly detection across lighting and apparatus conditions

Detection F1 across held-out standard, optical-stress and unseen 6-vial racks (0.6 to 1.0 scale)

Held-out multi-vial rack (standard) 0.9024
Dim, glare and mirror stress 0.8990
Zero-shot unseen 6-vial FreeClimber rack 0.7077
Execution: 13.4 FPS on CPU · 590 FPS on GPU

Individual assay endpoints

4 measured metrics
EndpointScoreBenchmark detail
Held-out multi-vial detection F10.902494.83% precision and 86.08% recall across densely populated climbing vials
Fly center localization2.03 pxMean absolute centroid error (1.99 px MAE on unseen 6-vial rack)
Optical perturbation stability0.897 to 0.901F1 retained across low-light, acrylic glare and mirror-reflection stress tests
Zero-shot 6-vial rack transfer0.7077 F1Out-of-box detection on an unseen FreeClimber camera and rack geometry

Evaluated under baseline lighting, dim exposure, specular glass glare, mirror reflections and zero-shot transfer to an unseen 6-vial apparatus.

Dataset: Public multi-vial RING recordings plus unseen 6-vial FreeClimber geotaxis rack

Cellular and tissue microscopy segmentation

Instance segmentation and sub-nuclear spot counting across four histological stains, high-throughput fluorescence plates and irradiated nuclei.

3 validated suites
10Tissue · 1,044 sections across 4 stains1st of 8 published toolsLive in browser and desktop

Multi-Stain Tissue Segmentation (CellBinDB)

Across 1,044 tissue sections spanning DAPI, ssDNA, H&E and multiplex immunofluorescence, ConductVision ranks first among eight segmentation tools overall and first on multiplex panels.

F1 0.73
1st of 8 tools across 4 stains
0.80 F1 on multiplex immunofluorescence · ahead of Cellpose 3 (0.70) and StarDist (0.65)
Instance F1 across 1,044 multi-stain tissue sections

Ranked against seven published segmentation baselines on CellBinDB (0.2 to 0.85 scale)

ConductVision 0.73
Cellpose 3 0.70
StarDist 0.65
SAM 0.63
Cellpose 1 0.61
MEDIAR 0.60
DeepCell 0.45
CellProfiler 0.34
Execution: Interactive tile and whole-section inference in browser and desktop

Individual assay endpoints

3 measured metrics
EndpointScoreBenchmark detail
Overall 4-stain instance F10.73 (1st of 8)Dice 0.76, precision 0.82 and recall 0.66 across 1,044 tissue sections
Multiplex immunofluorescence (mIF)0.80 F1 (1st)Highest single-modality instance accuracy across dense membrane and nuclear markers
Lead over generalist baselines+0.03 to +0.39 F1Ahead of Cellpose 3 (0.70), StarDist (0.65), SAM (0.63), DeepCell (0.45) and CellProfiler (0.34)

Instance F1 and Dice scored with the benchmark protocol across all four staining modalities without per-slide threshold tuning.

Dataset: CellBinDB benchmark · 1,044 annotated tissue sections across DAPI, ssDNA, H&E and mIF modalities

11Cells · 200 BBBC039 fields + 106 DSB images1st of 6 on BBBC039 Test-50Live in browser and desktop

Fluorescence Nuclei Segmentation (BBBC039 and DSB Stage 2)

On high-throughput chemical-screen fluorescence nuclei in BBBC039, ConductVision places first among six methods on the multi-threshold Test-50 split and generalizes zero-shot to Data Science Bowl Stage 2.

0.907
BBBC039 Test-50 average F1
95% CI 0.886 to 0.922 · 0.957 F1@0.5 across all 200 fields · 0.862 on DSB Stage 2
BBBC039 held-out Test-50 multi-threshold instance F1

Mean F1 across IoU 0.50 to 0.90 against published BBBC039 baselines (0.75 to 0.95 scale)

ConductVision 0.907
U-Net (Caicedo et al.) 0.898
DeepCell 0.858
CellProfiler 0.811
Execution: Interactive plate and field segmentation in browser and desktop

Individual assay endpoints

3 measured metrics
EndpointScoreBenchmark detail
BBBC039 Test-50 average F1 (IoU 0.5 to 0.9)0.907 (1st of 6)95% CI 0.886 to 0.922; ahead of U-Net (0.898), DeepCell (0.858) and CellProfiler (0.811)
BBBC039 full 200-field F1 at IoU 0.50.957Only 8.8% missed nuclei at strict IoU 0.7 across crowded and dividing cell fields
Data Science Bowl Stage 2 out-of-distribution F1@0.50.86295% CI 0.823 to 0.896 across 106 diverse test images (above CellProfiler 0.819, near top of 739 entries at 0.889)

Average F1 swept across IoU thresholds from 0.50 to 0.90 on the official 50-image test split with bootstrap 95% confidence intervals.

Dataset: Broad Bioimage Benchmark Collection BBBC039 (200 fields) and 2018 Data Science Bowl Stage 2 (106 test images)

12Nuclei · 90 held-out fluorescence images0.79 spot F1 · 0.78 count ICCLive in browser and desktop

Irradiated-Cell Nuclear Foci (gamma-H2AX Spots)

On 90 held-out fluorescence micrographs of irradiated cells, ConductVision detects individual gamma-H2AX DNA damage foci inside segmented nuclei with 0.84 precision and 0.78 count concordance.

F1 0.79
Sub-nuclear spot detection F1
0.84 precision · 0.75 recall · 0.78 per-nucleus count ICC vs. expert annotations
Sub-nuclear gamma-H2AX spot detection and count concordance

Held-out test precision, F1, intraclass count agreement and recall across 90 images (0.5 to 1.0 scale)

Spot detection precision 0.84
Spot detection F1 0.79
Per-nucleus count agreement (ICC) 0.78
Spot detection recall 0.75
Execution: Batch multi-channel foci counting in browser and desktop

Individual assay endpoints

3 measured metrics
EndpointScoreBenchmark detail
Puncta detection F10.79Balanced spot localization across sparse low-dose and overlapping high-dose foci
Spot precision and recall0.84 / 0.75Low false-positive rate inside DAPI-masked nuclear boundaries
Per-cell foci count ICC0.78Intraclass correlation against manual expert spot counts per nucleus

Joint nuclear boundary segmentation and sub-nuclear puncta localization scored by point-matching F1 and per-cell intraclass correlation.

Dataset: Irradiated-cell nuclear foci benchmark · 90 held-out test images with expert spot coordinates

Evaluation protocol

Every benchmark follows held-out subject splits and public evaluation metrics so labs can audit performance before adoption.

Held-out splits and subject separation

Every score comes from recordings or microscopy fields excluded from model training. Multi-recording behavioral classifiers use leave-one-video-out or leave-one-mouse-out cross-validation so background lighting, cage bedding and individual animal appearance never leak between training and evaluation.

Published software and human-rater baselines

Comparator scores for EthoVision XT, DeepLabCut, DeepEthoProfile, Cellpose, StarDist, SAM, U-Net, DeepCell and CellProfiler come from the published benchmark papers or released checkpoints on identical splits. Human agreement figures report pairwise concordance across independent manual scorers on identical frames.

Browser and workstation execution

All twelve pipelines export standard CSV and JSON measurements with frame-rate and coordinate manifests. CPU speeds were timed single-socket with ONNX Runtime on standard x86 workstation cores, and GPU speeds were timed with CUDA execution on a single data-center GPU.

Test ConductVision on your own arena or microscope footage.

Upload a short clip in the browser for immediate coordinates and zone tables, or install the workstation demo for batch offline runs.