Showing all 10 results
The Anesthesia Machine Pole Mount is a type of mount that is used to securely attach an anesthesia machine to a pole in a veterinary setting. This allows for easy positioning of the machine while freeing up valuable floor space. The pole mount is designed to ensure the stability and safety of the machine, helping to prevent accidents and equipment failure.
Our R620 enhanced mobile upgrade version is a Small Animal Anesthesia Machine that can move freely. Applicable to a variety of animals: mice, rats, guinea pigs, rabbits, cats, and other animals within 7 kg can be applied.
Anesthesia breathing bags are devices used in the administration of anesthesia. They are used to manually ventilate a patient during surgery when a mechanical ventilator is not available. The bags come in various sizes and are made of latex or latex-free materials. They are connected to an anesthesia machine or a simple oxygen source, and the clinician squeezes the bag to deliver breaths to the patient.
A rodent anesthesia breathing circuit is a system that delivers anesthetic gases to a small rodent during surgical procedures.
The anesthetic gas is delivered to the animal through the circuit tubing, allowing the animal to breathe in the anesthetic and maintain unconsciousness throughout the procedure. The rebreathing bag captures exhaled gases and recycles them back into the circuit, helping to conserve the anesthetic gas. The reservoir bag acts as a backup supply of oxygen, while the gas scavenging system captures and removes waste anesthetic gases from the environment.
Endotracheal tubes (ETT) are used in anesthesia to maintain an open airway during surgery. They are inserted into the trachea through the mouth or nose and secure in place with a cuff that seals the trachea and prevents air from leaking. ETTs are connected to an anesthesia machine and a breathing circuit for mechanical ventilation. ETTs also protect the airway from aspirating stomach contents and secretions. Comes in a pack of 100 units.
1 set of 10 = $28
1 pack of 10 sets = $25/each
Our Gas Canister Filter is used to absorb isoflurane and sevoflurane in anesthetic waste gas to prevent the anesthetic contamination of the operating room to the veterinarian.
The Anesthesia gas filter canister is a device used in medical anesthesia systems to filter and purify inhaled anesthetic gases. The canister contains a filter element that removes impurities, such as moisture and particulate matter, from the anesthetic gas mixture before it reaches the rodent. This helps to ensure that the animal is breathing clean and pure anesthetic gases, reducing the risk of breathing problems or other adverse effects during a medical procedure.
The filter canister is typically replaced periodically, depending on the type of filter and the amount of usage, to maintain its effectiveness.
The Nitrous Oxide Flowmeter Kit is used to measure the flow rate of nitrous oxide in an anesthesia system. The expansion chamber in a nitrous oxide flowmeter allows for the pressure of the gas to increase, causing the gas to expand. This expansion is then measured and used to calculate the flow rate of the gas. The flowmeter helps to ensure that the right amount of nitrous oxide is delivered to the patient, helping to maintain a safe and effective level of anesthesia during a medical procedure.
Oxygen Flowmeter is used to accurately control the gas flow rate. The flowmeter mounting plate and fixing screws can be added to the RWD large and small animal anesthesia machine fixed bracket to control the air source input flow rate of the RWD anesthesia machine.
And with the international standard ISO connector, the lower end is connected with an 8mm PVC pipe or silicone tube for gas source input, and the upper end is connected to the evaporator through a short section of 6mm silicone tube.
In addition, the oxygen flow meter and the laughing gas flow meter can also be used in parallel. After the oxygen and the laughing gas are mixed, they are mixed with isoflurane or sevoflurane through the evaporator to output mixed anesthetic gas to achieve better anesthesia and analgesia.
Description This solution is specially used for neuroscience research. Unique stereotaxic frame nosecone masks are designed to combine the anesthesia system and stereotaxic location system, which […]
Rodent anesthesia systems typically use a two-channel flowmeter to monitor and control the flow of gases, such as oxygen and anesthesia, to the rodent. The two channels allow for separate measurement and control of the flow of each gas, ensuring proper and safe delivery of the gases during the surgical procedure.
An oxygen supply designed for veterinary clinical applications. Using the principle of molecular sieve pressure swing adsorption, using air as raw material, physical separation of high-purity oxygen meets the various clinical needs of veterinarians and is widely used in veterinary clinical operations, postoperative, ICU, and first aid oxygen supply.
The Veterinary oxygen concentrator is a device that is used to provide supplemental oxygen to animals. The concentrator works by separating oxygen from the air, increasing the concentration of oxygen, and delivering it to the animal through a mask or other delivery device. Oxygen concentrators can provide a continuous supply of oxygen, making them a convenient and efficient way to support animals with breathing difficulties or other medical conditions that require supplemental oxygen. In a veterinary setting, oxygen concentrators are used to help animals recover from surgery or other medical procedures, or to treat conditions such as respiratory distress or heart disease.